EN UA
Hot Line: 8 800 200 05 65


Products

Fireproof slab for the insulation of structures made of TechnoNICOL

Fireproof slab for the insulation of structures made of TechnoNICOL

Application areas

– Thermal insulation and fireproofing of concrete structures in civil and industrial applications during new construction and reconstruction of various buildings and structures;
– Increases the fire-resistance limit of concrete structures and floor structures to 240 minutes.

Description of material

Fireproof TECHNONICOL slabs for insulation of concrete structures are nonfl ammable, heat- and sound-insulating slabs made of basalt rock stonewool. It can be manufactured also with aluminum foil or a fiberglass mat coating.

Storage

The slabs must be stored in covered warehouses. Storage under an awning protecting the slabs from atmospheric precipitation is permitted. When stored, slabs should be laid in containers or in piles on pallets or linings. The piling height during storage should not exceed 2 m.



Basic physical and mechanical properties

PropertyFireproof slab for the insulation of structures made of TechnoNICOL concrete
Density, kg/m3100
Thermal conductivity, W/m*C 100,034
250,036
1250,043
3000,087
A0,040
B0,041
Length, mm 1200
Width, mm 600,1200
Thickness, mm40-200

* In coordination with the customer a slab with the dimensions 12002400 mm can be produced on pallets.